Control Chief TM6000 Manuel de l'opérateur Page 141

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 201
  • Table des matières
  • DEPANNAGE
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 140
TM 10-3930-660-10
0012 00-17
PREVENTIVE MAINTENANCE CHECKS AND SERVICES (PMCS) - CONTINUED 0012 00
Table 1. Preventive Maintenance Checks and Services (PMCS) for 6K Forklift - Continued.
Item
No. Interval
Man-
Hours
Location
Procedure
NOT FULLY MISSION
CAPABLE IF:
Item To
Check/
Service
45 Weekly Batteries
WARNING
To avoid injury, eye protection and acid-resistant gloves
must be worn when working around batteries. Do not
smoke, use open flame, make sparks or create other igni-
tion sources around batteries, If a battery is giving off
gases, it can explode and cause injury to personnel.
Remove all jewelry such as rings, ID tags, watches, and
bracelets. If jewelry or a tool contacts a battery terminal, a
direct short will result in instant heating, damage to equip-
ment, and injury to personnel.
Sulfuric acid contained in batteries can cause serious burns.
If battery corrosion or electrolyte makes contact with skin,
eyes or clothing, take immediate action to stop the corro-
sive burning effects. Failure to follow these procedure may
result in death or serious injury to personnel.
CAUTION
To reduce battery damage, check battery compartment for
corrosion (greenish/white powder) and do NOT jerk or pull
on battery cables during visual inspection.
a. Access batteries by removing
battery box cover.
b. Check battery hold-down for
looseness or damage.
Hold-down is loose or damaged.
c. Inspect batteries for a cracked
case and evidence of leaking.
Battery case is cracked or leaks
are evident.