TM 10-3930-660-10
0017 00-4
PRIMARY AND SECONDARY AIR FILTER MAINTENANCE - CONTINUED 0017 00
INSTALLATION
1. DO NOT install element until it is dry.
2. Inspect element for damage. Place a bright light inside
the element and rotate element slowly. If any rupture,
holes or damaged gaskets are discovered, replace the
element.
3. If a new element is to be installed, inspect the element
and gasket for shipping and storage damage.
4. Install the primary filter element in the air cleaner can-
ister and secure with the wing nut.
5. Install outer cover. Turn thumbscrew to tighten clamp.
6. Install the outer cover and clamp. Tighten the thumb-
screw.
7. Check the rubber evacuator valve to be sure it is not
plugged or damaged.
8. Reset the air intake restriction indicator by pressing
button on end of indicator.
END OF WORK PACKAGE
409-065
WING
NUT
PRIMARY AIR FILTER
409-069
OUTER
COVER
THUMBSCREW
EVACUATOR
VALVE